1. Preliminary assessment
Likely failed flashing at the chimney penetration, with water tracking along the purlin into the passage ceiling. Assessed urgency: Priority.
2. Technician verification
On-site inspection confirmed perished sealant and a lifted apron flashing on the northern chimney face. Two adjacent sheet fixings were found under-torqued. No structural timber decay observed.
3. Photographic evidence
Twelve photographs recorded: overall roof plane, chimney detail before, ceiling staining, fixings, gutter line, and the same details after completion.
4. Recommended works
Remove and replace apron flashing, re-seal the penetration, replace four fixings and re-torque adjacent sheets. Repaint the affected ceiling area after a dry-out period.
5. Quote
Itemised materials and labour, valid 30 days, with the workmanship warranty period stated on the same page.